{"id":883,"date":"2023-02-28T01:28:11","date_gmt":"2023-02-28T01:28:11","guid":{"rendered":"https:\/\/shop.wind-fgw.de\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-power-generation-units\/"},"modified":"2023-04-14T01:14:24","modified_gmt":"2023-04-14T01:14:24","slug":"tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units","status":"publish","type":"product","link":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/","title":{"rendered":"TR 9 &#8211; Determination of high-frequency emissions from regenerative power generation units"},"content":{"rendered":"<p>The basic aim of the Technical Guideline Part 9 &#8211; EMC is to present the state of the art. The guideline cites existing and formulates industry-specific necessities.<\/p>\n<p>Issues related to the practical measurement of EMC emissions in relation to the limits of the applicable standards\/determination of high-frequency emissions from regenerative feeders will be discussed. Content issues include:<\/p>\n<ul>\n<li>How can the currently applicable standard (IEC\/CISPR 11, after confirmation by BNetzA and DKE 767.11.11) be supplemented or replaced for regenerative feeders in such a way that the conformity uncertainty is minimized?<\/li>\n<li>How can it be made possible to implement a type test despite a &#8220;measurement at the place of installation and operation&#8221;?<\/li>\n<\/ul>\n<p>The Technical Guideline is to be developed as a test basis for manufacturers, operators and measuring institutes and for feeding into European and international standardization.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The basic aim of the Technical Guideline Part 9 &#8211; EMC is to present the state of the art. The guideline cites existing and formulates industry-specific necessities. Issues related to the practical measurement of EMC emissions in relation to the limits of the applicable standards\/determination&#8230;<\/p>\n","protected":false},"featured_media":473,"template":"","meta":{"_acf_changed":false,"_themeisle_gutenberg_block_has_review":false},"product_brand":[],"product_cat":[143],"product_tag":[],"class_list":{"0":"post-883","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-technical-guidelines","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"purchasable","13":"product-type-variable"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\" \/>\n<meta property=\"og:description\" content=\"The basic aim of the Technical Guideline Part 9 &#8211; EMC is to present the state of the art. The guideline cites existing and formulates industry-specific necessities. Issues related to the practical measurement of EMC emissions in relation to the limits of the applicable standards\/determination...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/\" \/>\n<meta property=\"og:site_name\" content=\"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\" \/>\n<meta property=\"article:modified_time\" content=\"2023-04-14T01:14:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png\" \/>\n\t<meta property=\"og:image:width\" content=\"926\" \/>\n\t<meta property=\"og:image:height\" content=\"732\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/\",\"url\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/\",\"name\":\"TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\",\"isPartOf\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png\",\"datePublished\":\"2023-02-28T01:28:11+00:00\",\"dateModified\":\"2023-04-14T01:14:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage\",\"url\":\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png\",\"contentUrl\":\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png\",\"width\":926,\"height\":732},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/shop.wind-fgw.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/shop.wind-fgw.de\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TR 9 &#8211; Determination of high-frequency emissions from regenerative power generation units\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/shop.wind-fgw.de\/#website\",\"url\":\"https:\/\/shop.wind-fgw.de\/\",\"name\":\"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/shop.wind-fgw.de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/shop.wind-fgw.de\/#organization\",\"name\":\"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\",\"url\":\"https:\/\/shop.wind-fgw.de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/shop.wind-fgw.de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/02\/FGW-Logo.png\",\"contentUrl\":\"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/02\/FGW-Logo.png\",\"width\":222,\"height\":139,\"caption\":\"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien\"},\"image\":{\"@id\":\"https:\/\/shop.wind-fgw.de\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/","og_locale":"en_US","og_type":"article","og_title":"TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","og_description":"The basic aim of the Technical Guideline Part 9 &#8211; EMC is to present the state of the art. The guideline cites existing and formulates industry-specific necessities. Issues related to the practical measurement of EMC emissions in relation to the limits of the applicable standards\/determination...","og_url":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/","og_site_name":"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","article_modified_time":"2023-04-14T01:14:24+00:00","og_image":[{"width":926,"height":732,"url":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/","url":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/","name":"TR 9 - Determination of high-frequency emissions from regenerative power generation units - FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","isPartOf":{"@id":"https:\/\/shop.wind-fgw.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage"},"image":{"@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage"},"thumbnailUrl":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png","datePublished":"2023-02-28T01:28:11+00:00","dateModified":"2023-04-14T01:14:24+00:00","breadcrumb":{"@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#primaryimage","url":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png","contentUrl":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/03\/TR9-min.png","width":926,"height":732},{"@type":"BreadcrumbList","@id":"https:\/\/shop.wind-fgw.de\/en\/produkt\/tr-9-determination-of-high-frequency-emissions-from-regenerative-energy-generating-units\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/shop.wind-fgw.de\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/shop.wind-fgw.de\/shop\/"},{"@type":"ListItem","position":3,"name":"TR 9 &#8211; Determination of high-frequency emissions from regenerative power generation units"}]},{"@type":"WebSite","@id":"https:\/\/shop.wind-fgw.de\/#website","url":"https:\/\/shop.wind-fgw.de\/","name":"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","description":"","publisher":{"@id":"https:\/\/shop.wind-fgw.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/shop.wind-fgw.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/shop.wind-fgw.de\/#organization","name":"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien","url":"https:\/\/shop.wind-fgw.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/shop.wind-fgw.de\/#\/schema\/logo\/image\/","url":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/02\/FGW-Logo.png","contentUrl":"https:\/\/shop.wind-fgw.de\/wp-content\/uploads\/2023\/02\/FGW-Logo.png","width":222,"height":139,"caption":"FGW e.V. \u2013 Online-Shop f\u00fcr Referenzzertifikate, technische Richtlinien und Leistungskennlinien"},"image":{"@id":"https:\/\/shop.wind-fgw.de\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_action":{"enabled":false,"date":"2026-04-23 05:37:35","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"product_brand","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/product\/883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/media\/473"}],"wp:attachment":[{"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/media?parent=883"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/product_brand?post=883"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/product_cat?post=883"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.wind-fgw.de\/en\/wp-json\/wp\/v2\/product_tag?post=883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}